About Dp50rb
About Dp50rb
Blog Article
Aid 4D probe; understand the probe by way of the ID code; change the 4D drive signal by means of the electrical relay for making the 4D probe operate Typically. four.two.two Main board The leading board can be divided into two sections: entrance-conclusion of the primary board and again-end of the principle board.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Get a whole and prolonged look at in the anatomical construction by means of panoramic imaging coupled with velocity indication and ahead/backward scan ability earning scanning much simpler, smoother plus more controllable.
Will not use any cables in addition to the cables presented Along with the gadget by Mindray. three. Make use of the cable presented with This method to connect the printer. Other cables may well cause electrical shock. Web site 15: Mechanical Basic safety
By continuing your go to on our Web page, you're consenting to our usage of cookies. Nevertheless, you can modify your cookie options Anytime. Cookie desire Settle for and Move forward
Whenever you quit the scanning and the graphic seize, it is best to energy off the system and disconnect the technique within the AC electric power source, then pull out AC power cables. Webpage 109: Battery Connecting Board
Webpage one hundred forty five Thoroughly clean user interface Tools: dry smooth cloth, gentle soapy h2o Approach: Use dry tender cloth to wash the floor from the process. When the technique is filthy, moisten the gentle cloth with delicate soapy h2o and wipe off any stains. Use dry gentle cloth to get rid of any moisture and allow all tricky surfaces to entirely air-dry. Site 146: Clean up The Peripherals
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
Assessing sufferers in today’s demanding atmosphere demands revolutionary engineering that enables clinicians to create quick and self-assured diagnoses. The versatility from the DP-fifty expands your medical utility whilst assisting to increase individual treatment.
five.two.three Geometric positioning accuracy Longitudinal geometric positioning accuracy Test Phase: Do changes as the best way in tests the maximum depth. History the space by 20mm Each and every segment within the longitudinal targets line utilizing the measurement caliper; Pick out the value with the greatest error (to 20mm), estimate the precision utilizing the formula underneath The measurement caliper ought to be positioned at the upper edge of the goal, NOTE:... Site seventy nine Transverse geometric positioning accuracy Examination Action: Cover the scan area of the phantom with drinking water or couple gel, Carefully Get in touch with the probe With all the scan surface area Regulate the depth, earning the transverse targets to generally be exhibited from the picture. Modify the main focus position for being posited beside the transverse targets (the regular is not apparent) Change parameters like obtain, TGC, creating each transverse targets to generally be Plainly displayed. Site 80 five.5.2.four Blackout Location Test Action: Protect the scan surface of the phantom with water or pair gel, Carefully Speak to the probe Together with the scan surface Alter the depth at a decrease price, and set the main focus at the closest place to the scan surface area. Minimize the value of parameters like AP, Achieve until the track record sounds just can be witnessed. Web site 81: Application Enhance And Maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Observe: In advance of uploading the log, ensure that the ultrasound process has actually been linked to network, in any other case, the program could warn “couldn't connect with server” The server (smtp.
Performance Examination 5.five.1 Exam Course of action Resolution Detection depth Geometric Situation Accuracy Blackout region examination Document the exam pictures five.five.2 Check Articles The graphic applied here is just for reference, persist with the graphic result in the real Take note: predicament. Specifications: Display: set the distinction and brightness on the scientific application price (or maybe the default status) Operation atmosphere: darkish home, simulating the clinical application natural environment. Webpage 76 In problem which the transverse resolution screening targets are horizontally exhibited, record the nominal distance of two targets that can be Obviously acknowledged. Repeat the Procedure previously mentioned for your transverse resolution screening targets at other depths. As demonstrated in figure under. Axial resolution ... Site seventy seven When using the convex probe, hold the transverse resolution testing targets to NOTE: be exhibited close to the midline. When utilizing a linear probe with steer perform, usually do not turn on the steer function when perform the transverse resolution test. Zoom within the region where by the targets Positioned if needed. The diameter in the concentrate on place at a certain depth is equivalent for Dp50rb the transverse resolution in the depth. Web site 78 five.
Mindray respects your privateness. We use cookies for various reasons, for instance Web-site features, increasing your working experience of our Web page, constructing integration with social networking and helping focus on our marketing.
NOTE: Ensure that you could potentially pull out and drive into your IO board sockets vertically when pulling out and assembling the IO board assembly within the position on the tackle. Eliminate panhead screws with washers M3X6 (4) used to secure the IO board, after which you could potentially take out the IO board. Web page 116 Get rid of panhead screws with washers (2 M3X6) that are set on the key device, choose out the higher baffle then pull out two cables connecting the principle board to the power module assembly.